A reference from NEUTRALOX® Umwelttechnik GmbH. More references from NEUTRALOX® Umwelttechnik GmbH

NEUTRALOX® Photoionisation: South America

Treated media: Municipal wastewater

Flow rate: 1.200 m³/h

Substances: Hydrogen Sulfide

Processes: Photoionisation

Commissioning: 2014

KF Company: Neutralox GmbH

Sewage pumping station SA-000

This NEUTRALOX® Photoionisation unit handles high concentrated odors, originating from a sewage pumping station. The H₂S concentrations usually vary between 50 and 150 ppm, accompanied by other reduced sulfur compounds.

The NEUTRALOX® Photoionisation reduces the overall odor to below 500 OU/m³.

 

ATEX: Zone 2
H₂S Input: 150 ppm H₂S
Power demand: 1,8 KW
Dimensions: 1,600 x 2,240 x 3,090 mm

Contact person at Neutralox GmbH

Do you have any questions about our services. Then we look forward to your contact request!

Oliver Augustin
Geschäftsführer